Description
GPD 515
General Purpose AC-Drive 3/4 - 500 HP
50 Years of AC Drive Technology
Fifty years ago, MagneTek provided adjustable frequency drives in the form of variable-speed-driven alternators. In the ë60s, MagneTek introduced solid-state thyristor inverters to replace the alternator, significantly reducing the cost of adjustable frequency drives.
In the early '70s, we introduced the first commercially-available Current Source AC drive. Although there was a price premium, AC drive performance was unmatched. This drive embodied the fundamental control concepts found in todayís vector control drive.
Throughout the '80s, PWM technology improved, both in performance and reliability, and in the late '80s, MagneTek brought one of the most advanced microprocessor-based PWM AC drives to market.
In 1990, MagneTek introduced the IGBT-based GPD 503 with instant success and dominant market position, followed by the VCD 703, flux vector control drive.
Now, MagneTek introduces the next technological achievement, the GPD 515. Backed by 50 years of continuous advancements, the GPD 515 utilizes state-of-the-art IGBTs, SMDs, ASICs, 32 bit processing, motor algorithms, auto-tuning, and other benefit-laden technologies creating the cutting edge in AC drive design.
The most spectacular achievement is the flexibility provided to our customer, with a single drive platform offering traditional V/Hz, sensorless vector, and flux vector control performance.
Combined with MagneTekís inverter-duty induction motors, no competitive drive can match the torque and speed performance of the GPD 515 - the worldís most flexible drive.
Performance Features
Protective Features
Design Features
Vector Control Features
Service Conditions
Options
Control Methods
Performance Features
Ratings:
0.75 to 100 HP at 208 VAC,
0.75 to 100 HP at 230 VAC,
0.75 to 500 HP at 460 VAC
Overload capacity: 150% for 60 sec (200% peak)
Starting torque: 150%
Electronic reversing
Adjustable accel/decel: 0.1 to 6000 sec
Controlled speed range:
(1) 40:1,
(2) 100:1,
(3) 1000:1
Drive efficiency: 96 to 98%
Displacement power factor: 0.98
Output frequency: 0.1 to 400 Hz
Jog forward and reverse
Power loss ride-thru: 2 sec
Inertia ride-thru
Selectable auto restart after
momentary power loss
Programmable auto restart (0 to 10 attempts) on resettable fault
Critical frequency rejection: 3 selectable, adjustable bands
Protective Features
DC bus CHARGE indicator
Optically-Isolated controls
Phase-to-phase / phase-to-neutral
short circuit protection
Ground fault protection
Electronic motor overload (UL)
Current and torque limit
Overtorque/undertorque detection
Fault circuit: overcurrent,
overvoltage, and overtemperature
Input/output phase loss
Design Features
32-bit logic, including 16-bit DSP
Carrier frequency to 15 kHz, rating dependent
Alpha-numeric operator, removable,
multi-lingual, 2 lines x 16 character
24 VDC control logic
Programmable outputs.
One form A and two open collector
Timer function
RS-232 communication port
9 Multi-speed settings
Remote speed reference:
-10 to +10 VDC (20K ohms) or
4 to 20 mA (250 ohms)
Setpoint (PID) control
Signal follower: bias and gain
Analog monitor output:
-10 to +10 VDC proportional to output parameters
DC bus reactor:
25 to 100 HP at 230 VAC,
30 to 250 HP at 460 VAC
Dual motor parameter sets
Auto-tune to motor characteristics
Common bus capability
Programmable flash ROM,
via RS232C, for custom applications
Run and fault contacts (1A)
Up / down / hold reference
Fully EMC compliant when optional RFI filter connected
NEMA 1 enclosed or protected chassis
MTBF: exceeds 28 years
Vector Control Features
Speed resolution:
0.01% with digital reference
0.1% with analog reference
Speed regulation: (15º to 35ºC)
(2) 0.1% with digital reference
(3) 0.01% with digital reference
(3) 0.1% analog reference
(3) Encoder response: 300kHz
(3) PG card, A/B/Z ph line driver, +5 or +12v
(3) Stall torque: to 150% at zero speed for 1 minute, 100% continuous Volts/Hertz Features
DC injection braking:
ramp or coast to stop,
adj. current limited to 60% motor rating
Frequency resolution:
0.01 Hz with digital reference
0.06 Hz with analog reference
Frequency regulation (15º to 35ºC):
0.01% with digital ref; 0.1% with analog ref
Torque boost: full range, auto
Current limited stall prevention during accel, decel and run
Synchronized start into rotating
motor via speed search
V/Hz ratio: 15 preset; 1 infinitely-adj.
Slip compensation
Service Conditions
Ambient service temperature:
-10ºC to 40ºC (104ºF) NEMA 1,
to 45ºC (113ºF) protected chassis
Humidity: to 95% non-condensing
Altitude: to 3300 ft; higher by derating
Input voltage: +10%/-15%,
200 to 230 VAC, 380 to 460 VAC
3-phase sequence insensitive
UL listed; cUL listed; IEC: 146A
Options
Remote operator stations
Pressure to electrical transducer
Input breaker, disconnect, fuses,
NEMA 4 and 12 enclosures
RS-485 communication port
Isolation transformer
Analog monitor, precision
Digital or pulse monitor output
Two additional form C contacts
Synchronous motor operation
Dynamic braking
Dual PG card (digital follower)
Upload/download software
(1) 800 Hz output
(3) Motor-mounted encoder
Control Methods:
(1) Volts/Hertz
(2) Sensorless vector (open loop)
(3) Flux Vector (closed loop)
--------------------------------------------------------------------------------
|